Bus and Truck Spray Booth
We design Bus and Truck Spray Booth for the finishing applications of numerous large-size vehicles and large equipment, such as buses, trucks, couches, vans, trailers, trains, ships, yachts and plane spare parts.
Multiple custom length, width and height, and mass state-of-the-art technical options are available in YOKISTAR Truck and Large Spray Booths to accommodate various customer requirements.
YOKISTAR Truck and Large Spray Booths achieve superb quality and durable performance to guarantee the most efficient coating operation, the fastest curing times and lowest operating costs.
Bus and Truck Spray Booth
YS-TB15 Specification
The Air Draft Way: by pits.
Floor Arrangement: 2 rows of the pit made of 30x4mm flat bar and 10mm twisted steel grill, with surface galvanised treatment, loading weight is 600KG/wheel. The dimension for each pit is 12650x760mm(LxW).
Supporting Frame: made of square steel tube, 40x80mm(WxL).
Floor Filter: Fiberglass filter laid on the filter frame, G3 Grade(EN779), model is PA-50, filtering area: 19.2M2
Inside Size: 15000x5000x5000mm(LxWxH).
Outside Size: 15144x6896x5600mm(LxWxH).
Entrance door: Electric shutter, size is 4000×4600mm(W×H), the sheet is made of aluminium alloy frame with PU insulation.
Personnel Door: 1 unit, 800x2000mm(WxH); square viewing glass window with aluminium alloy frame.
Wall Panel: 70mm thick and 1000mm wide, insulation is EPS and covered by 0.426mm thick of colour steel inside and outside. Tongue and groove interlock structure, all sides surrounded by steel.
Roof Panel: 50mm thick and 1000mm wide, insulation is EPS and covered by 0.426mm thick of colour steel inside and outside. Tongue and groove interlock structure, all sides surrounded by steel.
Ceiling Light: Left and right upper positions have nine lighting fixtures, 18 fixtures in total. Each fixture is equipped with 4 PHILLIP fluorescent tubes of 36 Watt with two in one electronic ballast.
Side Light: Left and right bottom positions have 11 lighting fixtures, 22 fixtures in total. Each fixture is equipped with 4 PHILLIP fluorescent tubes of 36 Watt with two in one electronic ballast. Up and bottom cross installation.
Plenum: 600mm high, cross beam and longitude beam of plenum are made of galvanised bent steel and treated by white powder for long using life.
Ceiling Filter: Supporting net is made of C shape steel with surface oil painted treatment,sub-high efficiency filter, F5 Grade(EN779), type is SP-600G.
Frame Size: 2200x1600x2400mm(LxWxH).
Cabinet Materials: Frame is made of 50×50mm square tube welded, with PU insulation inside.
Motor and Fan
Motor type: inside of the fan; motor qty.:2 pcs; single motor power:7.5KW, total power:15KW;
Fan type: double intake centrifugal fan, YDW5.6M, total air capacity: 42000m3/h
Makeup Air Control: Belimo 10N electric actuator controls fresh air quantity/pressure.
Pneumatic Actuator: Control the air valve opening or closing while the active status is spraying or baking.
Heat Exchanger: Qty: 1pc; single heat exchanger power: 232KW, made of 1.5mm stainless steel 1Gr18Ni9Ti(SUS304), With round type multi-cycle radiator pipe, equipped with safe anti-explosion hole.
Burner: Riello RG5S diesel burner, heating productivity is 260,000Kcal/H, qty.:1pc.
1m stainless steel chimney, 3m bent galvanised steel chimney and 1pc rain shield.
Filtering: Pre-filter, G2 Grade(EN779),type is C16-100 ;Fibre glass filter, G3 Grade(EN779),type is PA-50 .
Frame Size: 1600x1600x1850mm(LxWxH).
Cabinet Materials: Frame is made of 50×50mm square tube welded, with PU insulation inside.
Motor and Fan:
Motor type:belt-drive; qty.:1 pc; single motor power:11KW, total power:11KW;
Fan type: double intake centrifugal fan, TAE-710H, total air capacity: 36000m3/h
Exhaust Air Control: Handed Actuator for controlling VCD air valve be opened or closed.
Exhaust Air Duct: 4pcs straight duct(1000x1000x1000mm LxWxH), 1pc 90°elbow duct, 1pc 30° elbow duct.
Filtering: Fibreglass filter, G3 Grade(EN779),type is PA-50 .Granular Active Carbon in “M” Shape Filter Frame.
Spraying、Heat Spraying, Baking, Baking Time Setting, Light Switch, Failure Indicator, Temperature Controller, Power Switch, Emergency Stop, Hour Meter, Temperature Limiter, Ampere Meter, Voltmeter, Pressure Gauge, Pressure Alarm, Air Exhaust Reduced-Voltage Starter.
Options for your choosing
VFDs Control
The frequency can be controlled by inverter to achieve much more energy saving.
PLC Control
An intellectualized control with the integration of intermediate relay, time relay analog signal and so on; saving space dramatically, easy control and highly intellectualized.
Touch-Screen Control
Turning traditional knob-and-button control into touch-screen control; saving space dramatically, easy control, better screen showing (in conjunction with PLC)
Automatic Pressure Alarm System
Setting a most reasonable pressure rating, once the pressure in the booth out of your setting, the system will alarm and booth will stop working for the safety of people working in the booth
Would you like to know the price for Bus and Truck Spray Booth(YS-TB12 and YS-TB15)?